ASTM F1891 – Standard Specification for Arc and Flame Resistant Rainwear
This USA standard set the specifications for arc and Flame Resistant Rainwear. It addresses laminated and coated materials and state the minimum performance specifications for Arc Flash protective rainwear as well as minimum requirement of flame resistance and mechanical durability of fabrics and subassemblies used.
Additional to the ASTM 1506, the material and the seams of the rainwear must be tested for water penetration/leakage.
The major requirement of this standard is that the fabric used must be Arc Rated, tested for an Electric Open Arc to receive an ATPV-value. This is done by testing according to ASTM F1959.
The protection lies in the flame retardant properties of the garment and at what level the material takes up the heat energy discharged at an arc (this is stated in cal/cm²). The higher the ability of the material or material combination to absorb the energy, the higher the protective function of the garment.
ASTM F1891 is not a base for certification, it’s a validation standard.
ASTM F1959 – Standard Test Method for Determining the Arc Rating of Materials for Clothing
ASTM F959 is the USA standard test method for Determining the Arc Rating of Materials for Clothing. The purpose of this test method is to determine how much energy a fabric, or fabric combination, will block from an electric arc without causing a second-degree burn injury.
The test exposes panels of flame resistant fabrics to electric arc flashes of varying energies. The result is reported as the ATPV-Value.
ATPV-Value (Arc Thermal Performance Value) indicates the amount of energy (cal/cm²) to which the material/garment can be exposed and still provide a 50% protection against the second degree’s burn injury.
If the fabric breaks open at a lower value than the ATPV-rating, the reported value is the Energy Breakopen Threshold (Ebt).
EBT-Value (Energy Break Open Threshold) indicates the amount of energy (cal/cm²) to which the material/garment may be exposed before a 50% risk of hole formation occurs.
The ATPV-value (or Ebt-value) shall be reported for all garments that meets the ASTM 1506 or ASTM 1891 standards. Blåkläder’s FR-garments are marked externally with the Arc Flash PPE Category and the ATPV value.
The protection lies in the flame retardant properties of the garment and at what level the material takes up the heat energy discharged at an arc (this is stated in cal/cm²). The higher the ability of the material or material combination to absorb the energy, the higher the protective function of the garment.
ASTM F1959/1959M is not a base for certification, it specifies a test methodology.